Multimode test standard compliance

What it does

Our LED sources / loss test sets are Encircled Flux compliant. This applies to equipment produced since 2007.

This means they have a defined modal fill, to achieve consistent loss measurement between different items of test equipment.

Our LED source beam profile meets :

  • IEC 61280-4-1 Ed 2 Encircled Flux standards, at 850 nm into 50 u core fiber.
  • IEC 61300-1 Ed 2 "Equilibrium Modal Distribution" or "CPR or Coupled Power Ratio": Coupled Power Ratio Category 1 for 850 / 1300 nm, and 50 and 62.5u core fiber.

Kingfisher encircled flux compliance certificate

Standards compliant test methods

User benefits

Improves test consistency.

Simplifies loss testing, since special test leads are not required.

Avoids purchase, maintenance & management of expensive EF compliant test reference leads.

In field use, we found that with Kingfisher EF compliant LED sources, multimode test uncertainty is typically limited by randomly changing the test leads. If mandrels are also used, variability can be further improved. Expected test uncertainty is explored in further detail in Application Note.

The role of mandrel wraps

It is often wrongly assumed that a mandrel wrap can be used to create an EMD, CPR or EF modal condition. With modern multimode fiber, it does no such thing.

What a mandrel does do, is to strip off unstable edge modes, and so generally improve measurement consistency.

Kingfisher provides a pair of TIA-568-C.0 compliant mandrels with every LED source, for 50 u and 62.5 u core fiber. See brochure of mandrels for more detail.

Standards Compliant Mandrel Wrap

FOTP-50 Method A

Multimode Test Standards Compliant Instruments


KI 9600A Pocket Power Meter

  • Simple shirt-pocket size power meter
  • Options for all networks & users
  • Low-skill TamperLock mode
  • Ideal for transmission installers

ISO17025 traceable ILAC / NATA / ISO17025 Traceable Calibration

KI 2600 Handheld Power Meter

  • Productivity power meter
  • Options for all networks & users
  • Ideal for cable installers
  • Powerful reporting capability
  • Optional VFL

ISO17025 traceable ILAC / NATA / ISO17025 Traceable Calibration

KI 6102 GPON / PON Power Meter

  • Economical in-line meter for PON test
  • Simple and reliable operation
  • 1310 / 1490 / 1550 nm, two ports
  • 100 test memory with PC software
KI 9800A Pocket Fiber Source

  • Economical shirt-pocket size source
  • Options for SM, MM, POF etc
  • Low-skill TamperLock mode
  • MM is EF compliant
  • Eye safe high power VFL 5 mW
KI 6358 Pen Visual Fault Finder

  • Pen-sized universal VFL 1mW
  • Eye safe class 1 laser
  • LC / 1.25 mm universal adapter option
KI 2800 Handheld Source

  • Versatile productivity source
  • Options for SM, MM, POF etc
  • SM + MM quad up to 6 λ
  • Unique VisiTester VFL

ISO17025 traceable ILAC / NATA / ISO17025 Traceable Calibration

KI 2400 Handheld Source with Zero Warm-up

  • Unique Zero Warm-up, optically stabilized source
  • Ultimate stability over temperature & ORL
  • Up to 6 SM λ
  • eLED option for precise loss & CD testing

ISO17025 traceable ILAC / NATA / ISO17025 Traceable Calibration

KI 6610 FiberSafe Microscope

  • Microscope for inspection of SM, MM, MPO and POF networks
  • Best quality and image
  • Wide range of interchangeable adaptors
  • Many helpful features

 

KI 6680 Fiber Inspection Probe

  • Scope to check mated & unmated connectors SM, MM, MPO
  • Software for Windows, Apple or Android devices
  • Wifi or USB connection
  • Easy operation

 

KI 7340 Handheld Two-Way Loss Test Set with ORL & Zero Warm-Up

  • Fastest & most accurate certifier
  • Bi-directional Loss & ORL on one fiber
  • Zero warm up time sources
  • Pass / Fail display

ISO17025 traceable ILAC / NATA / ISO17025 Traceable Calibration

KI 7740 Handheld Two-Way Loss Test Set

  • Fastest fiber optic certifier
  • Bi-directional loss on one fiber
  • Pass / Fail display

ISO17025 traceable ILAC / NATA / ISO17025 Traceable Calibration

KI 2700 Handheld Loss Test Set

  • Versatile Loss Test Set
  • VFL-VisiTester option
  • SM, MM & Quad versions
  • MPO CS POF versions

ISO17025 traceable ILAC / NATA / ISO17025 Traceable Calibration

KI 2300 Handheld Loss Test Set with Zero Warm-Up

  • Highest accuracy OLTS
  • Zero warm-up time sources
  • Singlemode fiber only

ISO17025 traceable ILAC / NATA / ISO17025 Traceable Calibration

KI 6170 Clip-on fiber identifier

  • Clip-on to check for traffic or test tones
  • Low false detection rate
  • Optical Power display 
  • Requires a light source with tone facility
KI 7010 Series Variable Optical Attenuator

  • SM, MM & POF versions
  • Best optical specifications
  • Easy to use, rugged & reliable
  • Remote control vis RS232

ISO17025 traceable ILAC / NATA / ISO17025 Traceable Calibration

Hybrid Adaptor Series

  • Sources, attenuators, OLTS
  • Most power meters except XL series
  • G2 connector
  • Useful to make test adapter leads
XL Series Power Meter Adaptor Series

  • Large area XL series power meters
  • Legacy KI6000 power meters
  • Also fits other instruments
KI66xx Microscope Adaptor Series

  • KI661x FiberSafe Optical Microscope
Miscellaneous Accessories

Various accessories and kit components for Kingfisher testers.

MPO Patch Cords & Test Leads

Test Grade MPO Patch Leads to improve your test accuracy

Fiber Test Leads

Test Grade SC and LC Patch Leads to improve your test accuracy

Single mode, multimode, PC, APC

Cold Clamp (buried cable fault locator)

  • Use liquid nitrogen to induce a non-destructive optical marker
  • Use with OTDR to localize physical fault within 1m
  • Significantly improve real-world response & labor time
  • Works on live systems
KI-UBENCH

POF air-gap collimator assembly useful to place bulk optics devices, sensors or samples into plastic optical fiber light path.

G2 Panel Mount Connector Series

  • Universal Optical Connector for OEM, test & production
  • For connectors with 2.5 & 1.25 mm ferrule, SMA, POF and others