Application Notes

Here Kingfisher's experienced engineers share their experience in best practices and procedures for fiber optic testing related mostly to installation and maintenance. We hope that by sharing our knowledge, we will help grow our industry. Please enjoy & pass on these notes. Alternatively, browse Standards related Test Procedures, Equipment & Reporting

Which loss measurement wavelengths do I need?

Introduction

Fiber optic loss testing is usually performed at expected current and future operating wavelengths, since optical loss can vary widely across the range of potential operating wavelengths.

Fiber Type Most common
operating λ nm
Common
operating λ nm
Typical loss
tests λ nm
Source
Type
Other λ nm Out of band
loss tests λ nm
Plastic 1 mm 650   650 LED    
PCS 200u 650 850 650 / 850 LED    
Glass multimode 50/125, 62.5/125 850 1300 850 / 1300 LED 1270 - 1610 CWDM  
Glass single mode 9.5/125, Traditional 1310 1550 1310 / 1550 Laser   >1580
Glass single mode 9.5/125, DWDM C band
1525 - 1565
L band
1570 - 1610
1550 / 1610 Laser S band
≈ 1420 - 1530
1625
Glass single mode 9.5/125, CWDM 1310, 1490, 1550 1270 - 1610 1310, 1490, 1550 Laser 1383 1625

It has been standard practice for many years to perform single mode fiber tests at 1550 nm (in addition to 1310 nm), to help find identify cabling stress points. Typically, a kinked cable may pass at 1310 nm, but fail at 1550 nm or beyond.

Laser sources are unsuitable for work on multimode fiber, since very unstable power meter fiber optic power readings are obtained. For optimum multimode accuracy, a mandrel wrap and a LED source with standards compliant characteristics are required.

DWDM

 C band systems may only be loss tested at 1550 nm. C & L band systems are typically loss tested at 1550 / 1625 nm. The S band is currently somewhat ill-defined, and may run into the fiber water absorption peak, so loss measurement will need to be at the shortest relevant wavelength, and 1550 nm.

CWDM

 Attenuation in CWDM systems is usually measured at only a few wavelengths and varies quite substantially depending on the application and fiber type. The water absorption peak at 1383 nm may require evaluating, and a selected "1383 nm" laser is needed for this task. Most current systems avoid the water peak wavelength area due to this potential loss problem. Loss checking of passive CWDM channel filters requires specific CWDM compliant light sources.

"Out of band" single mode

 Has been traditionally specified as "1625" nm. This has traditionally used Fabry-Perot lasers with poor spectral accuracy. New DFB lasers have much better properties for this application, since their actual operating wavelength is more tightly controlled (see table below). For true WDM compliance, the out of band wavelength must be <1620 nm.
There is also an emerging class of "1650" nm OTDRs, however their usually poor wavelength accuracy and high cost makes them less useful.

 
Nominal
center λ
Laser Type Center λ Tolerance
@ 25 °C
Center λ
Range @ 25 °C
Typ Center λ
/ °C coefficient
Center λ
Range 0 - 50 °C
Typ λ Width
FWHM, nm
Total λ Range
0 - 50 °C, FWHM
Power meter
detector type
1310 nm Fabry-Perot ± 30 nm 1280 - 1340 ± 0.4 1270 - 1350 3 1268.5 - 1351.5 Ge or InGaAs
1550 nm Fabry-Perot ± 30 nm 1520 - 1580 ± 0.4 1510 - 1590 3 1508.5 - 1591.5 Ge or InGaAs
CWDM DFB ± 3 nm 1270 - 1610 nm ± 0.1 ±5.5 nm 0.1   InGaAs
1610 nm DFB ± 3 nm 1607 - 1613 ± 0.1 1604.5 - 1615.5 0.1 1604.5 - 1615.5 InGaAs
1625 nm DFB ± 5 nm 1620 - 1630 ± 0.1 1617.5 - 1632.5 0.1 1617.5 - 1632.5 InGaAs
1625 nm Fabry-Perot ± 30 nm 1595 - 1655 ± 0.4 1585 - 1665 3 1583.5 - 1667.5 InGaAs
1650 nm Fabry-Perot ± 30 nm 1620 - 1680 ± 0.4 1610 - 1690 3 1608.5 - 1691.5 InGaAs

This illustrative graph shows how typical single mode fiber attenuation varies with wavelength. It may not be exactly accurate
Modern fibers may have a negligible water absorption peak at 1.38 µ
Wavelength uncertainly of tests above 1600 nm can have a major impact on loss measurement.

 

Fiber-Spectral-Loss-history
© Kingfisher International, Australia, ABN 51 007 250 213