Overview

A handheld fiber power meter for laboratory, QA and manufacturing use, to accurately test power, loss, continuity and faults on single mode fiber optic systems and free-space beams up to +10 dBm. Ideal for: Single mode, multimode, multi-fiber ribbon cable such as MMC, MPO 12 - 72 fiber up to 12 fibers wide, and LC/ SC etc fiber optic systems This full-feature instrument has comprehensive report generation capabilities and a variety of useful features for maximum productivity and flexibility. 
Optional connector adapter not included, order separately.

  • Easy to use, rugged & versatile
  • 27 calibration λ, 1% accuracy ISO/IEC 17025 traceable
  • Improved high power accuracy
  • Autotest with up to 3 λ displayed
  • Long battery life & micro USB external power
  • Large back-lit LCD, sunlight readable
  • Interchangeable optical connectors
  • Large memory with text naming & time stamp
  • KITS™ reporting software with data security
  • One button memory dump to USB Flash Drive
  • MultiFiber ID tone detection
  • Full QA & linearity test report

Key Features

Specifications

KI2600XL-INGAAS5 specifications
Detector type InGaAs (5 mm)
 
Response wavelength 600 ~ 1700 nm
 
Calibration wavelengths 780, 820, 850, 880, 910, 940, 980, 1270, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
 
Power range +10 ~ -50 dBm (for 780 ~ 940 nm) / +10 ~ -60 dBm (for 980 ~ 1650 nm)
 
Mid-range linearity 0.04 dB
 
Wavelength sensitivity (± 30 nm) 0.2dB (typical)
 
Response uniformity across detector 1 % (0.06 dB)
 
ID tone detection & Autotest sensitivity -40 dBm
 
Country of Origin Australia
 
Shipping Weight 1500 g
 
General Handheld Power Meter KI 2600 Series specifications
Calibration accuracy ±1 % (0.06 dB)
 
Calibration validity 3 years (ISO/IEC 17025)
 
Resolution 0.01 dB
 
Polarization sensitivity < 0.05 dB (typical)
 
Tone detection 150 ~ 9999 Hz ± 1 %
 
Power 2x AA (LR6) Alkaline / External via micro-USB
 
Battery life Up to 1000 hours
 
Auto-off Selectable
 
USB interfaces micro-USB for power & software / USB-A Flash Drive
 
Software KITS (free download)
 
Memory 1000 (4-λ tests) / Unlimited on USB Flash Drive
 
Size 124 x 81 x 25 mm
 
Unit weight 0.42 Kg
 
Shipping weight 1.5 kg
 
Operating / storage temperatures -15 to 55 °C / -25 to 70 °C
 
Relative humidity 0 ~ 95 %
 
Warranty 3 years
 
IP Rating IP52
 

Documentation & Support

Applications

In the box

Please note: A connector adapter is not included with this product. When ordering, please ensure you also order a compatible connector adapter (listed below).

Padded Canvas Carry Pouch OPT149

Soft pouch for two KI2000 series instruments. With carry straps and compartments for accessories storage.

Software (KITS)

Downloadable from Kingfisher's website for free.

Optional accessories

OPT226A

LC Connector Adapter - XL Power Meter, OPT226A

LC Simplex. For duplex LC use OPT224

OPT224

1.25 mm Universal Connector Adapter - XL Power Meter, OPT224

1.25 mm Universal. Also fits duplex LC

OPT225

2.5 mm Universal Connector Adapter - XL Power Meter, OPT225

2.5 mm Universal. Also fits duplex SC

OPT205
OPT227

MPO Connector Adapter - XL Power Meter, OPT227

MTP™ / MPO 12 x n style with central key. For XL power meters with a 5 or 7 mm detector For both MM & SM fiber.

OPT233
OPT201-POF
OPT203

SMA POF Connector Adapter - XL Power Meter, OPT203

SMA for POF with large pin-hole

OPT202-POF
OPT204-POF
OPT229

POF-Multi Connector Adapter - XL Power Meter, OPT229

HFBR simplex and duplex, Mini Toslink, bare POF cable,, 2.5mm. Multi-Purpose POF Adapter for power meters. Turn the turret to the required hole size: 3.85, 3.5, 3.2, 2.55, 2.4, 2.3 mm, x 8.5 mm deep. For SMA connectors, use OPT203.

OPT230
OPT231

HFBR POF Connector Adapter - XL Power Meter, OPT231

For simplex / duplex / latching / non-latching POF HFBR, Versatile Link, Redlink connectors.

OPT401

MPO/MTP Classic Reel Cleaner OPT401

A classic MPO end-face cleaner for both mated and unmated connectors.

TOOL CLEAN-05A

Stick-Type, MPO Connector Cleaner TOOL CLEAN-05A

To clean MPO end face, particularly around the alignment pins.

OPT154B

Semi-Rigid Carry Case for Test Kits OPT154B

Semi-rigid canvas test kit case for two KI2000 series instruments, three KI900 series instruments, optical microscope & VFL pen. With cleaning materials, carry straps and compartments for accessories storage. Moulded interior provides a perfect combination of durability, protection, and comfortable use.

OPT153-CASE

Semi-Rigid Carry Case for Test Kits OPT153-CASE

Semi-rigid canvas test kit case for two KI2000 or KI7000 series instruments, and three KI9000 series instruments. With carry straps and compartments for accessories storage. Moulded interior provides a perfect combination of durability, protection, and comfortable use.

TOOL CLEAN-09A

Fiber Connector Cleaner Cartridge TOOL CLEAN-09A

To clean a connector end face / tip, prior to connector insertion into a mating adaptor.

TOOL CLEAN-03

Stick-Type Cleaner 2.5 mm TOOL CLEAN-03

To clean the end face and mating sleeve of a fiber optic connector with 2.5 mm diameter ferrule. SC, FC, ST etc.

TOOL CLEAN-04

Stick-type Cleaner 1.25 mm TOOL CLEAN-04

To clean the end face and mating sleeve of a fiber optic connector with 1.25 mm diameter ferrule, LC, SN etc

© Kingfisher International, Australia, ABN 51 007 250 213